BFSI (EMC)

Power cable 0,6/1 kV halogen – free, low smoke fire resistant cable with Cu conductors

BFSI (EMC)

APPLICATION

Fire resistant security cables for installation everywhere where high safety requirements have a special significance e.g., in industrial complexes, power stations, public buildings, hotels, underground railway systems, hospitals etc. The copper screen can have 100% covering and complies with the EMC directive with right practicable installation.
Installations in the open air, underground, indoors, in cable ducts. Not suitable for use in water. Cables may be layed directly in ground if installed properly and carefully acc. to REN leaf 9000 guide

CERTIFICATES


CONSTRUCTION

  • Sheath
    HFFR compound, type ST8 acc. to IEC 60502-1
  • Bedding
    Extruded elastomere or plastomere halogen-free compound or plastic halogen-free tape
  • Conductors
    Cu, class 1 or 2 according to EN 60228
  • Insulation
    Mica tape and XLPE compound over it
  • Concentric conductor
    Cu foil tape (optional), Cu wires with counter helix of Cu tape

TEHNICAL CHARACTERISTICS

  • Standard
    HD 604 5D, IEC 6052-1 IEC 60331-21, EN 60332-1-2, EN 60332-3-24, EN 61034-2, EN 60754-1, EN 60754-2
  • CPR class
  • Test voltage
    4 kV
  • Rated voltage
    0,6/1 kV
  • Core identification
    Acc.to HD 308 S2
  • Min.bending radius
    single-core - 15D; multicore - 12D
  • Min.laying temperature
    -20°C
  • Max.operating temperature
    90°C
  • Max.short-circuit temperature
    250°C
  • Lowest temp.for fixed installation
    -40°C
Nominal cross-section Conductor construction Max. Resistance at 20°C Current capacity in air Current capacity in earth Outer diam. (approx.)
mm2 Ω/km A A mm
2x1,5/1,5 RE 12,1/12,1 14,2 - 14,2
2x2,5/2,5 RE 7,41/7,41 33 - 15
2x4/4 RE 4,61/4,61 43 - 16,3
2x6/6 RE 3,08/3,08 54 - 17,6
2x10/10 RE 1,83/1,83 75 - 19,3
2x16/16 RE 1,15/1,15 100 - 21,1
2x25/16 RM 0,727/1,15 136 - 25,9
2x35/16 RM 0,524/1,15 165 - 28
3x1,5/1,5 RE 12,1/12,1 25 - 14,8
3x2,5/2,5 RE 7,41/7,41 33 - 15,6
3x4/4 RE 4,61/4,61 43 - 17
3x4/4 RM 4,61/4,61 43 - 17,7
3x6/6 RE 3,08/3,08 54 - 18,4
3x6/6 RM 3,08/3,08 54 - 18,8
3x10/10 RE 1,83/1,83 75 - 20,2
3x10/10 RM 1,83/1,83 75 - 20,8
3x16/16 RE 1,15/1,15 100 - 22,1
3x16/16 RM 1,15/1,15 100 - 23
3x25/16 RM 0,727/1,15 136 - 27,3
3x35/16 RM 0,524/1,15 165 - 29,6
3x50/25 SM 0,387/0,727 201 - 29,7
3x70/35 SM 0,268/0,524 255 - 33,6
3x95/50 SM 0,193/0,387 314 - 36,7
3x120/70 SM 0,153/0,268 364 - 40,5
3x150/70 SM 0,124/0,268 416 - 44,7
3x185/95 SM 0,0991/0,193 480 - 48,6
3x240/120 SM 0,0754/0,153 565 - 54,6
4x1,5/1,5 RE 12,1/12,1 25 - 15,8
4x2,5/2,5 RE 7,41/7,41 33 - 16,7
4x4/4 RE 4,61 43 - 18,2
4x6/6 RE 3,08/3,08 54 - 19,7
4x6/6 RM 3,08/3,08 54 - 20,7
4x10/10 RE 1,83/1,83 75 - 21,7
4x10/10 RM 1,83/1,83 75 - 22,4
4x16/16 RE 1,15/1,15 100 - 23,9
4x16/16 RM 1,15/1,15 100 - 24,9
4x25/16 RM 0,727/1,15 136 - 29,7
4x35/16 RM 0,524/1,15 165 - 32,2
4x35/16 SM 0,524/1,15 165 - 29,8
4x50/25 SM 0,387/0,727 201 - 33,2
4x70/35 SM 0,268/0,524 255 - 37,6
4x95/50 SM 0,193/0,387 314 - 41,3
4x120/70 SM 0,153/0,268 364 - 46,1
4x150/70 SM 0,124/0,268 416 - 50,1
4x185/95 SM 0,0991/0,193 480 - 54,8
4x240/120 SM 0,0754/0,153 565 - 61,4
5x1,5/1,5 RE 12,1/12,1 25 - 16,8
5x2,5/2,5 RE 7,41/7,41 33 - 17,9
5x4/4 RE 4,61/4,61 43 - 19,5
5x6/6 RE 3,08/3,08 54 - 21,1
5x10/10 RE 1,83/1,83 75 - 23,4
5x16/16 RE 1,15/1,15 100 - 25,8
  • *Permissible current rating values are according to:
  • - three-phase circut
  • - laying depth of 0,8m for buried cables
  • K=1 - resistivity of the ground equal to 1,0K-m/W
  • K=1,5 - resistivity of the ground equal to 1,5K-m/W