LV (0,6/1 kV) power cables with PVC insulation and PVC sheath

EAYY

APPLICATION

In earth, ducts, on support brackets, in dry and wet conditions etc., where one does not expect mechanical damages and the cables are not exposed to the mechanical tensile strain. In urban networks, industrial plants, electric power plants and other electricity  consumers and for connection of control devices in industry, traffic etc.

CERTIFICATES


CONSTRUCTION

  • Sheath
    PVC compound, type DMV 1
  • Bedding
    Extruded elastomere or plastomere compound or plastic tape
  • Conductors
    Al conductor, class 1 or 2, acc. to EN 60228
  • Insulation
    PVC compound, type DIV 1

TEHNICAL CHARACTERISTICS

  • Standard
    HD 603 S1, ÖVE E 8200-603, IEC 60502-1
  • CPR class
    Eca
  • Test voltage
    4 kV
  • Rated voltage
    0,6/1 kV
  • Core identification
    Acc. to HD 308 S2
  • Bending radius (min)
    Single-core 15D; multi-core 12D
  • Min. laying temperature
    -5°C
  • Max. operating temperature
    70°C
  • Max. short-circuit temperature
    160°C
Nominal cross-section Conductor construction Max. Resistance at 20°C Current capacity in air Current capacity in earth Outer diam. (approx.)
mm2 Ω/km A A mm
1x16 RM/RE 1,910 - - 10,5
1x25 RM 1,200 87 106 12
1x35 RM 0,868 107 127 13,5
1x50 RM 0,641 131 151 15
1x70 RM 0,443 166 185 17
1x95 RM 0,320 205 222 19
1x120 RM 0,253 239 253 20
1x150 RM 0,206 273 284 22
1x185 RM 0,164 317 322 25
1x240 RM 0,125 378 375 28
1x300 RM 0,100 437 425 30
1x400 RM 0,0778 513 487 34
1x500 RM 0,0605 600 558 37
1x630 RM 0,0469 701 635 38,8
1x800 RM 0,0367 809 716 42,1
1x1000 RM 0,0291 916 796 46,6
3x16 RM/RE 1,910 - - 18,4
3x25 RM 1,200 82 102 21,7
3x35 RM 0,868 100 123 24,1
3x50 RM/SM 0,641 119 144 27,9
3x70 RM/SM 0,443 152 179 31,4
3x95 RM/SM 0,320 186 215 35,9
3x70+35 SM/SM 0,443/0,868 152 179 33
3x95+50 SM/SM 0,320/0,641 186 215 37,8
3x120+70 SM/SM 0,253/0,443 216 245 40,4
3x150+70 SM/SM 0,206/0,443 246 275 44,9
3x185+95 0,164/0,320 SM/SM 285 313 49
3x240/120 SM/SM 0,125/0,253 338 364 55,2
4x16 RM/RE 1,910 - - 24
4x25 RM 1,200 82 102 25
4x35 SM 0,868 100 123 28
4x50 SM 0,641 119 144 30
4x70 SM 0,443 152 179 35
4x95 SM 0,320 186 215 39
4x120 SM 0,253 216 245 41
4x150 SM 0,206 246 275 45
4x185 SM 0,164 285 313 49
4x240 SM 0,125 338 364 55
4x300 SM 0,100 400 419 59
5x16 RM/RE 1,910 - - 23,4
5x25 RM 1,200 102 112 28,2
5x35 RM/SM 0,868 126 135 31
5x50 RM/SM 0,641 149 158 36,8
5x70 RM/SM 0,443 191 196 42,8
5x95 RM/SM 0,320 234 234 48,5
5x120 RM/SM 0,253 273 268 53,6
  • *Permissible current rating values are according to:
  • - three-phase circut
  • - laying depth of 0,8m for buried cables
  • K=1 - resistivity of the ground equal to 1,0K-m/W
  • K=1,5 - resistivity of the ground equal to 1,5K-m/W