Power cable 0,6/1 kV with Al conductors, PVC insulated and sheathed

NAYY

APPLICATION

In earth, ducts, on support brackets, in dry and wet conditions etc., where one does not expect mechanical damages and the cables are not exposed to the mechanical tensile strain. In urban networks, industrial plants, electric power plants and other electricity consumers and for connection of control devices in industry, traffic etc.

CERTIFICATES


CONSTRUCTION

  • Sheath
    PVC compound, type DMV 5
  • Bedding
    Extruded elastomere or plastomere compound or plastic tape
  • Conductors
    Al, class 1 or 2 according to EN 60228
  • Insulation
    PVC compound, type DIV 4

TEHNICAL CHARACTERISTICS

  • Standard
    VDE 0276-603, HD 603 S1, IEC 60502-1
  • CPR class
    Eca
  • Test voltage
    4 kV
  • Rated voltage
    0,6/1 kV
  • Min bending radius
    single-core - 15D; multicore - 12D
  • Core identification
    According to HD 308 S2
  • Min. laying temperature
    -5°C
  • Max. operating temperature
    70°C
  • Max. short-circuit temperature
    160°C
Nominal cross-section Conductor construction Max. Resistance at 20°C Current capacity in air Current capacity in earth Outer diam. (approx.)
mm2 Ω/km A A mm
1x16 RM 1,910 - - 10,5
1x25 RM 1,200 87 106 12
1x35 RM 0,868 107 127 13,5
1x50 RM 0,641 131 151 15
1x70 RM 0,443 166 185 17
1x95 RM 0,320 205 222 19
1x120 RM 0,253 239 253 20
1x150 RM 0,206 273 284 22
1x185 RM 0,164 317 322 25
1x240 RM 0,125 378 375 28
1x300 RM 0,100 437 425 30
1x400 RM 0,0778 513 487 34
1x500 RM 0,0605 600 558 37
1x630 RM 0,0469 701 635 38,8
1x800 RM 0,0367 809 716 42,1
1x1000 RM 0,0291 916 796 46,6
2x16 RM/RE 1,910 - - 17,4
2x25 RM 1,200 82 102 20,4
2x35 RM 0,868 100 123 22,6
2x50 RM 0,641 119 144 26
2x70 RM 0,443 152 179 29
2x95 RM 0,320 186 215 33,2
3x16 RM/RE 1,910 - - 18,4
3x25 RM/RE 1,200 82 102 21,7
3x35 RM 0,868 100 123 24,1
3x50 RM/SM 0,641 119 144 27,9
3x70 RM/SM 0,443 152 179 31,4
3x95 RM/SM 0,320 186 215 35,9
3x120 SM 0,253 216 245 39,7
3x150 SM 0,206 246 275 43,8
3x185 SM 0,164 285 313 48,3
3x240 SM 0,125 338 364 54,1
4x35 SE/SM 0,868 100 123 28
4x50 SE/SM 0,641 119 144 30
4x70 SE/SM 0,443 153 179 35
4x95 SE/SM 0,320 186 215 39
4x120 SE/SM 0,253 216 245 41
4x150 SE/SM 0,206 246 275 45
4x185 SE/SM 0,164 285 313 49
4x240 SE/SM 0,125 338 364 55
4x300 SE/SM 0,100 400 419 59
3x70+35 SM/SM 0,443/0,868 152 179 33
3x95+50 SM/SM 0,320/0,641 186 215 37,8
3x120+70 SM/SM 0,253/0,443 216 245 40,4
3x150+70 SM/SM 0,206/0,443 246 275 44,9
3x185+95 SM/SM 0,164/0,320 285 313 49
3x240+120 SM/SM 0,125/0,253 338 364 55,2
5x10 RE 3,080 - - 19
5x16 RE 1,910 - - 23,4
5x25 RM 1,200 82 102 28,2
5x35 RM 0,868 100 123 31
5x50 RM 0,641 119 144 36,8
5x70 RM 0,443 152 179 42,8
5x95 RM 0,320 186 215 48,5
5x120 RM 0,253 216 245 53,6
  • *Permissible current rating values are according to:
  • - three-phase circut
  • - laying depth of 0,8m for buried cables
  • K=1 - resistivity of the ground equal to 1,0K-m/W
  • K=1,5 - resistivity of the ground equal to 1,5K-m/W