PFSP Cu

Power cable 0,6/1 kV with Cu conductors, PVC insulated and sheathed, with concentric conductor

PFSP Cu

APPLICATION

Distribution power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions where there is a danger of possible mechanical damages, but where the cable is not exposed either to systematic mechanical stress or heavier tensile strain. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and other electric plants. Concentric conductor can be used as neutral, protective or earth connection, and in situations where the insulation might be roughly damaged by some metal object, it acts as protection against contact voltage. Corrugated, concentric conductor construction enables establishing of several cable connections without cutting of conductor.

CONSTRUCTION

  • Sheath
    PVC compound, type DMV 24
  • Bedding
    Extruded elastomere or plastomere compound or plastic tape
  • Conductors
    Cu conductors, class 1 or 2 according to EN 60228
  • Insulation
    PVC compound, type DIV 9
  • Concentric conductor
    Cu wires with counter helix of Cu tape

TEHNICAL CHARACTERISTICS

  • Standard
    HD 603 S1, p.3J
  • Test voltage
    4 kV
  • Rated voltage
    0,6/1 kV
  • Core identification
    According to HD 308 S2
  • Bending radius (min)
    12xD
  • Min. laying temperature
    -10°C
  • Max. operating temperature
    70°C
  • Max. short-circuit temperature
    160°C
Nominal cross-section Conductor construction Max. Resistance at 20°C Current capacity in air Current capacity in earth Outer diam. (approx.) Metal weight Cable weight (approx.)
mm2 Ω/km A A mm kg/km kg/km
2x6/6 AFR 3,08 43 57 14,4 445,2 410
2x10/10 AFR 1,830 60 77 17,2 192 620
3x16/16 AFR 1,150 80 100 19,3 307,2 861
3x25/16 AFR 0,727 102 130 22,3 480 1167
3x6/6 AFR 3,08 43 57 15,6 172,8 499
3x10/10 AFR 1,830 60 77 18,1 288 733
3x16/16 AFR 1,150 80 100 20,3 460,8 1032
3x25/16 AFR 0,727 102 130 23,6 720 1428
3x35/16 AFV 0,524 126 160 22,7 1008 1493
3x50/25 AFV 0,387 153 190 25,6 1440 2088
3x70/35 AFV 0,268 195 240 28,7 2016 2823
3x95/50 AFV 0,193 236 285 33,8 2736 3870
3x120/70 AFV 0,153 274 325 36,5 3456 4846
3x150/70 AFV 0,124 317 370 40,2 4320 5848
3x185/95 AFV 0,0991 361 420 45,1 5328 7338
3x240/120 AFV 0,0754 427 480 50,3 6912 9375
4x6/6 AFR 3,08 43 57 16,8 230,4 586
4x10/10 AFR 1,830 60 77 19,6 384 865
4x16/16 AFR 1,150 80 100 22 614,4 1228
4x25/16 AFR 0,727 102 130 25,7 960 1725
4x35/16 AFV 0,524 126 160 25,8 1344 1905
4x50/25 AFV 0,387 153 190 29,1 1920 2668
4x70/35 AFV 0,268 195 240 32,6 2688 3604
4x95/50 AFV 0,193 236 285 38 3648 4934
4x120/70 AFV 0,153 274 325 41,5 4608 6168
4x150/70 AFV 0,124 317 370 45,2 5760 7481
4x185/95 AFV 0,0991 361 420 50,6 7104 9355
4x240/120 AFV 0,0754 427 480 56,5 9216 11980
  • *Permissible current rating values are according to:
  • - three-phase circut
  • - laying depth of 0,8m for buried cables
  • K=1 - resistivity of the ground equal to 1,0K-m/W
  • K=1,5 - resistivity of the ground equal to 1,5K-m/W